Hinweise zur Veröffentlichung InstalSystem 5

Aus HelpSystem
Zur Navigation springen Zur Suche springen
Product InstalSystem 5
Type of article PRODUCT INFORMATION
Content up-to-date for version IS 5.0 Beta 27


Information zum Programmstand

Version BETA 27 Rev. 16.3.1

Modules:

Base module, including InstalSystem Manager

  • Improved function 'automatically connect terminal units'.
  • Made available the ability to configure the buttons to select a group of elements (SHIFT and CTRL).
  • Introduced possibility of selecting 'None' in the climatic data in case of lack of apropriate climatic data catalogue in the program.
  • Added the function of the graphic presentation of the route of flow from a given receiver to the source.
  • Added the function of the graphic presentation of routes flow from the source (manifold, source) to all receivers, which it supplies.

Radiant heating - dry systems

  • Introduced handling underfloor panels which lead the pipes in dry systems of radiant heating.

Version BETA 26 Rev. 16.2.1

Modules:

Base module, including InstalSystem Manager

  • Improved saving files in a network location.
  • Introduced the possibility to choose the source for which you want to appear the critical circuit.

Version BETA 25 Rev. 16.1.1

Modules:

Base module, including InstalSystem Manager

  • Added function that allows automatically connect terminal units.
  • Added possibility of quick creating rectangular room with sides parallel to the X, Y by drawing diagonal of the room.
  • The problem with sending Problem Report Form is eliminated.

Radiant heating - panel systems

  • Added function that allows connect panels in series.
  • Introduced the possibility to design heating/cooling installations using ceiling/wall panels (including radiant steel ceiling panels).
    Attention! Required upgrade to the configuration with the new module (InstalSystem Manager - tab "Upgrade").

Articles in HelpSystem:

Version BETA 24 Rev. 15.12.1

Warning! For this version of the program the reinstallation is necessary.

Modules:

Base module, including InstalSystem Manager

  • Improved stability and quality of the program.

Radiant heating - loop systems

  • Added a message about the lack of possibility for editing automatically generated pipe feeds/RHC loops.
  • Standarized the content of data table for heating/cooling zones at various ranges of editing.
  • Introduced permanent visibility of the field Pipe laying pattern in the data table for heating/cooling zones.
  • Fixed an error that occurs while connecting pipe feeds route to the heating/cooling zone.

Articles in HelpSystem:

Version BETA 23 Rev. 15.11.1

Modules:

Base module, including InstalSystem Manager

  • Fixed the problem with sending the Problem report form.
  • Added icons for the .isproj files displayed in the InstalSystem Manager and in the Windows Explorer's window.
  • The scope of the displayed catalogues in the general data has been adapted to the available project scope for the package.

Radiant heating - loop systems

  • Changed the designation of nodes in the grid which supports the manual drawing of the loop.
  • Added message box indicating the inability to remove the RHC loop.

Heating network with balancing

  • Fixed the automatic sizing of manifolds' cabinets.
  • Improved the propagation of the default data for manifold cabinet.

Articles in HelpSystem:

Version BETA 22 Rev. 15.10.1

Modules:

Base module, including InstalSystem Manager

  • Added graphical rulers (horizontal and vertical) to help verify the scale of loaded underlay.
  • Improved ORTO and AUTO modes.
  • Fixed the problem with sending error report form after crash of the program.
  • Improved overall stability and quality of the program by eliminating the reported errors.

Articles in HelpSystem:

Version BETA 21 Rev. 15.9.2

Modules:

Base module, including InstalSystem Manager

  • Modified the way of importing base drawing files.
  • Added a Select components in rectangle function under the left mouse button.
  • Improved acting of ORTO mode when moving objects.
  • Accelerated loading of the newly created or saved again files, as a consequence the files created on previous versions may load slower.

Radiant heating - loop systems

  • Added the possibility of parallel connection of several RHC loop to one common outlet from the manifold.
  • Introduced balance diagnostics of the RHC loop connected to the manifold with not integrated balancing valves, and the possibility of adding on the pipe-runs valves which are balancing these objects.

Heating network with balancing

  • Added the possibility to use multi-circuit heating floor zone.
  • Introduced balance diagnostics of the circuits by the heating floor zones in the systems without the manifold.
  • Added the possibility to supply multi-circuit heating floor zone from several manifolds.
  • Introduced the possibility of supplying heating/cooling zones directly from the virtual or graphical source, without the usage of a manifold.

Articles in HelpSystem:

Version BETA 16.1 Rev. 15.5.17

Modules:

Base module, including InstalSystem Manager

  • Added new tool to search and select items in the project.
  • Improved the import and export of bases.
  • Introduced the control of print range which based on the edition range and the elements' styles.
  • Introduced the possibility to highlight and select project's elements to which messages on the diagnostic list referred to.
  • Added the possibility to highlight on the worksheet elements forming the circuit of specified receptor from this worksheet.

Radiant heating - loop systems

  • Improved the functionality of pipe feed automatic generation.

Articles in HelpSystem:

Version BETA 15.1 Rev. 15.4.21

Initial scope of modules:

  • Base module, including InstalSystem Manager
  • Radiant heating - loop systems
  • Cooling mode for radiant systems
  • Heating network with balancing
  • BIM Interface (gbXML)

Initial state of articles in HelpSystem